Non-invasive three-dimensional electrical activation mapping to predict cardiac resynchronization therapy response: site of latest left ventricular activation relative to pacing site

EP Europace Journal

1 March 2023
Organised by: Logo
ESC Journals HEART FAILURE Chronic Heart Failure

Abstract

AbstractAims

Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response.

Methods and results

Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6–24 months of post-implant. Latest electrically activated site and the distance to LVPS (dp) were assessed. Left ventricular end-systolic volume (LVESV) reduction of ≥15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and dp. Of 111 studied patients [64 ± 11 years, EF 28 ± 6%, implant duration 12 ± 5 months (mean ± SD), 98% had LBBB, 38% IHD], 67% responded at 10 ± 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. dp was 42 ± 23 mm [31 ± 14 mm for responders vs. 63 ± 24 mm non-responders (P < 0.001)]. Longer dp and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. dp of 47 mm delineated responders and non-responders (AUC 0.931).

Conclusion

The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.

Contributors

Leonor Parreira
Leonor Parreira

Author

Hospital Center of Setubal Setubal , Portugal

Alexey Tsyganov
Alexey Tsyganov

Author

I.M. Sechenov First Moscow State Medical University Moscow , Russian Federation

Claudio Tondo
Claudio Tondo

Author

Centro Cardiologico Monzino-IRCCS Milano , Italy

Ciro Ascione
Ciro Ascione

Author

La Tour Hospital Geneva , Switzerland

Mathias Meine
Mathias Meine

Author

University Medical Center Utrecht Utrecht , Netherlands (The)

Philippe Wouters
Philippe Wouters

Author

University Medical Center Utrecht Utrecht , Netherlands (The)

Niraj Varma
Niraj Varma

Author

Cleveland Clinic Cleveland , United States of America