Non-invasive assessment of pulmonary vein isolation durability using late gadolinium enhancement magnetic resonance imaging

EP Europace Journal

20 September 2022
Organised by: Logo
ESC Journals ARRHYTHMIAS AND DEVICE THERAPY Atrial Fibrillation (AF) IMAGING Cardiac Magnetic Resonance (CMR)

Abstract

AbstractAims

Electrical reconnection of pulmonary veins (PVs) is considered an important determinant of recurrent atrial fibrillation (AF) after pulmonary vein isolation (PVI). To date, AF recurrences almost automatically trigger invasive repeat procedures, required to assess PVI durability. With recent technical advances, it is becoming increasingly common to find all PVs isolated in those repeat procedures. Thus, as ablation of extra-PV targets has failed to show benefit in randomized trials, more and more often these highly invasive procedures are performed only to rule out PV reconnection. Here we aim to define the ability of late gadolinium enhancement (LGE)-magnetic resonance imaging (MRI) to rule out PV reconnection non-invasively.

Methods and results

This study is based on a prospective registry in which all patients receive an LGE-MRI after AF ablation. Included were all patients that—after an initial PVI and post-ablation LGE-MRI—underwent an invasive repeat procedure, which served as a reference to determine the predictive value of non-invasive lesion assessment by LGE-MRI.: 152 patients and 304 PV pairs were analysed. LGE-MRI predicted electrical PV reconnection with high sensitivity (98.9%) but rather low specificity (55.6%). Of note, LGE lesions without discontinuation ruled out reconnection of the respective PV pair with a negative predictive value of 96.9%, and patients with complete LGE lesion sets encircling all PVs were highly unlikely to show any PV reconnection (negative predictive value: 94.4%).

Conclusion

LGE-MRI has the potential to guide selection of appropriate candidates and planning of the ablation strategy for repeat procedures and may help to identify patients that will not benefit from a redo-procedure if no ablation of extra-PV targets is intended.

Contributors

Jean-Baptiste Guichard
Jean-Baptiste Guichard

Author

Hospital Clinic of Barcelona Barcelona , Spain

Jose Maria Tolosana
Jose Maria Tolosana

Author

Hospital Clinic of Barcelona Barcelona , Spain

Eduard Guasch
Eduard Guasch

Author

Hospital Clinic of Barcelona Barcelona , Spain

Elena Arbelo
Elena Arbelo

Author

Hospital Clinic, University of Barcelona Barcelona , Spain

Andreu Porta-Sanchéz
Andreu Porta-Sanchéz

Author

Hospital Clinic of Barcelona Barcelona , Spain

Lluís Mont
Lluís Mont

Author

Hospital Clinic of Barcelona Barcelona , Spain

Till F Althoff
Till F Althoff

Author

German Heart Centre Berlin Berlin , Germany