Reliability of continuous single-lead patch ECG interpretation for atrial fibrillation detection: Insights from the NORSCREEN trial
European Heart Journal

Abstract
Accurate interpretation of ECG recordings is essential for the diagnosis of atrial fibrillation (AF). Previous studies have demonstrated moderate reliability of single-point single-lead ECG in the setting of AF screening, which limits its utility for widespread use in early detection.
To evaluate the inter-observer agreement in the detection of AF by independent cardiologists interpreting continuous single-lead patch ECG recordings.
The Norwegian AF Self-Screening Trial (NORSCREEN) is an ongoing randomized controlled trial enrolling adults aged ≥65 years with at least one additional risk factor for stroke. Individuals with a prior AF diagnosis or anticoagulation therapy are excluded. Included participants are randomly assigned to long-term (7-day) ECG monitoring using the continuous single-lead patch ECG system ECG247 (Figure 1). All ECG recordings undergo analyses by an automated algorithm before review by a cardiologist (first ECG interpretation). Cases initially interpreted as AF by the cardiologist are further assessed by a Data and Safety Monitoring Board (DSMB) comprising two independent cardiologists (second ECG interpretation). In cases of disagreement, a third independent cardiologist adjudicates the final diagnosis. Inter-observer reliability was defined as the level of positive percent agreement between the first and second ECG interpretations. Minimum 30 s AF was required for an AF interpretation.
The 121 first interpretation of AF among the study participants were included in this analysis. The median age was 73 [interquartile range: 69–77] years and 48% of the study participants were female. The median duration of the ECG recordings were 7 days [interquartile range: 5–9 days]. The second ECG interpretation confirmed AF in 120 cases, corresponding to 99.2% agreement with the first interpretation (Figure 2).
The NORSCREEN trial demonstrate high inter-observer reliability in the interpretation of continuous single-lead patch ECG for AF detection. These results highlight the potential of continuous single-lead ECG monitoring to enhance AF diagnosis, thereby improving early detection and facilitating timely intervention in at-risk population.