Micro-reentry right atrial tachycardia originating from fossa ovalis: a case report of high-density mapping by PentaRay catheter
European Heart Journal - Case Reports

Abstract
Micro-reentry tachycardia usually emerges in scar tissues related to post-atrial fibrillation ablation and cardiomyopathy. It is difficult to identify the micro-reentry circuit accurately by conventional mapping method.
A 74-year-old man presented with paroxysmal atrial tachycardia (AT) presenting as palpitations. He was evaluated by an electrophysiological examination using a high-density CARTO mapping system. The mapping results showed the AT with a cycle length of 184 ms was focused on his right atrial fossa ovalis (FO). In this small area, the high-density mapping demonstrated a significant micro-reentrant tachycardia. Radiofrequency ablation at the centre of the micro-reentrant circuit successfully terminated the AT. No recurrences were observed during a 12-month follow-up.
This case demonstrated a micro-reentrant AT originates from the FO without cardiomyopathy or previous ablation with specific loops. This is an unusual location for AT though and can cause difficulty for operators if it terminates or is non-sustained. High-density mapping using a PentaRay catheter can effectively characterize micro-reentrant circuits and determine the real target for ablation therapy.