CNNT DB-LGE: free-breathing dark blood late enhancement imaging using the convolutional neural network transformer speeds acquisition by 50%
European Heart Journal - Cardiovascular Imaging

Abstract
Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Supported in part by the Division of Intramural Research of the National Heart, Lung, and Blood Institute, National Institutes of Health (grants Z1A-HL006214-05 and Z1A-HL006242-02).
Dark blood late gadolinium enhancement (DB-LGE) imaging shows superior delineation of myocardial infarction (MI), especially at the sub-endocardial boundary. Our previous study [1] developed a free-breathing DB-LGE with the single shot SSFP readout, phase sensitive inversion recovery (PSIR) reconstruction, and respiratory motion corrected averaging. To compensate the potential signal-to-noise ratio loss, our previous DB-LGE doubled the measurements, thereby increasing the acquisition time.
In this study, we developed a deep learning image enhancement model using a novel neural network architecture called the convolutional neural network transformer (CNNT) to improve the image quality of DB-LGE and to reduce the acquisition time by decreasing the number of measurements.
A novel image enhancement model was developed using a novel network architecture called the Convolutional Neural Network Transformer (CNNT) proposed by us. This architecture is suitable for the 2D+Time CMR acquisition, by exploiting the temporal correlation between images over multiple averages.
The evaluation was first retrospectively conducted on a cohort of 12 patients acquired with the original protocol [1] using the full 16 measurements. For every subject, a complete short-axis stack (typically 12 slices) was acquired to cover the entire left ventricular. The imaging data was reconstructed in three ways. Original: using all acquired 16 measurements. This is our base-line protocol. Original 50%: using only the first 8 measurements. CNNT 50%: using only the first 8 averages, but performing the CNNT deep learning image enhancement before MOCO PSIR reconstruction. Two experienced imaging researchers (PK and MF, >10 years of experience for both) scored all DB-LGE images for the overall quality, diagnostic confidence and delineation of MI/boundaries (5 = excellent, 4 = good, 3 = fair, 2 = poor, and 1 = non-diagnostic). The CNNT DB-LGE was deployed to the MR scanner using the Gadgetron InlineAI [2].
A novel CNNT model was proposed and evaluated to speed up the free-breathing MOCO DB LGE by 50% without sacrificing image quality.