Transformation of computerized electrocardiogram data into novel means to differentiate wide complex tachycardias

European Heart Journal

3 October 2022
Organised by: Logo
ESC Journals

Abstract

AbstractBackground

Accurate automated wide QRS complex tachycardia (WCT) discrimination between ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) can be accomplished using novel calculations derived from computerized electrocardiogram (ECG) data from paired WCT and baseline ECGs.

Purpose

Our aim was to develop and trial novel WCT discrimination approaches for WCT patients with and without a corresponding baseline ECG. Central to this analysis was the creation and use of a novel parameter (i.e., percent monophasic time-voltage area [PMonoTVA] [%]) that may be derived from computerized ECG measurements present on the WCT ECG alone.

Methods

In a two-part study, we derived and tested WCT differentiation models comprised of novel and previously established parameters formulated from computerized data of paired WCT and baseline ECGs. In Part 1, novel and established parameters generated from WCT and baseline ECG data were used to derive, validate, and compare five different binary classification models: (i) logistic regression [LR], (ii) artificial neural network [ANN], (iii) Random Forests [RF], (iv) support vector machine [SVM], and (v) ensemble learning (EL). In Part 2, two unique LR models were derived, validated, and compared using parameters generated from computerized data of the (i) WCT ECG alone (i.e., Solo Model) and (ii) paired WCT and baseline ECGs (i.e., Paired Model).

Results

In Part 1, among 103 patients with VT or SWCT diagnoses established from corroborating electrophysiology studies or intra-cardiac device recordings, favorable diagnostic performance was achieved by all modeling technique subtypes: LR (area under the receiver operating characteristic curve [AUC] 0.95), ANN (AUC 0.91), RF (AUC 0.97), SVM (AUC 0.98), and EL (AUC 0.97). In Part 2, among 235 patients with a VT or SWCT diagnosis established with (Gold Standard cohort) or without (Non-Gold Standard cohort) a corroborating electrophysiology procedure or intra-cardiac device recording, favorable diagnostic performance was achieved by the Solo Model (AUC 0.86) and Paired Model (AUC 0.95) (Table).

Conclusion

Accurate WCT discrimination may be accomplished using novel parameters derived from computerized data of the WCT ECG alone and paired WCT and baseline ECGs.

Funding Acknowledgement

Type of funding sources: Public grant(s) – National budget only. Main funding source(s): National Institute of Health

Solo Model and Paired Model performance