Successful transseptal puncture through tortuous inferior vena cava with a novel transseptal guidewire: a case report
European Heart Journal - Case Reports

Abstract
Atrial transseptal puncture is a fundamental manoeuvre in transseptal transcatheter interventions, and inferior vena cava tortuosity could cause failure of conventional transseptal puncture method with Brockenbrough needle.
We report a rare case of inferior vena cava tortuosity in a patient with atrial fibrillation in which the conventional transseptal puncture method failed due to marked needle deformation and was completed by a novel transseptal wire (AccuSafe™, Synaptic Medical) in combination with a steerable sheath.
Inferior vena cava tortuosity is one of the major causes of unsuccessful atrial transseptal puncture, even under the guidance of intracardiac echocardiography. The new transseptal wire should be the initial selection rather than a conventional transseptal needle when encountering severe inferior vena cava tortuosity.
Contributors

Tongshuai Chen
Author

Yuhang Yang
Author

Bing Rong
Author

Jingquan Zhong
Author

Stefano Bordignon
Author

Vera Maslova
Author

Deepti Ranganathan
Author