AbstractBackground/introduction

Mechanical waves within the myocardium arising from physiologic events in the cardiac cycle such as the atrial kick (AK), mitral valve closure (MVC) and aortic valve closure (AVC) offer insight to tissue stiffness and can be measured by high frame rate echocardiography.

Purpose

To investigate the feasibility of measuring mechanical wave velocities in the left ventricle by clutter filter wave imaging (CFWI) and its potential for detecting regional myocardial dysfunction in patients with acute coronary syndrome.

Methods

We examined 60 patients (66±9 years of age, 72% male) with acute coronary syndrome by high frame rate echocardiography after revascularisation, imaging the left ventricle from the parasternal long axis view and three apical projections. Intrinsic mechanical waves generated by the AK, MVC and AVC were analysed off-line by CFWI of all walls using custom software (PyMWI) on 2000 frames of in-phase and quadrature component data per view extracted from a Vivid E95 scanner.

Results

We analysed a total number of 2372 waves recorded with a frame rate of 1180 (1134-1199) frames per second. The feasibility for measuring AK waves was high in all regions (mean 89%), but lower for the MVC and AVC waves with significant variability between regions (mean 44% and 46%, respectively; p<0.001). Feasibility declined from basal to apical segments for all waves (p=0.0001). Mean mechanical wave velocity was slowest for the AK wave at 2.5 (2.0-3.0) m/s, faster for the AVC wave at 5.1 (3.5-6.3) m/s and fastest for the MVC wave at 6.6 (4.9-8.6) m/s (p=0.0001). Basal AK wave velocity was faster in patients with basal wall motion abnormalities compared to those without (2.7 vs. 2.0 m/s, p=0.0004) and could detect the presence of wall motion abnormalities adjusting for age, gender and parameters of diastolic function (univariable OR 3.4, 95% CI 1.5-7.7, p<0.01; multivariable OR 4.4, 95% CI 1.4-14.1, p=0.01). Basal AK wave velocity detected wall motion abnormalities with an AUC of 0.78 with cut-off speeds of 2.3 m/s and 3.0 m/s, both correctly classifying 73% of cases (sensitivity/specificity 81%/68% and 43%/89%, respectively). Mechanical wave velocities of other waves and in other regions were not consistently and only weakly associated with echocardiographic parameters of systolic and diastolic function.

Conclusion(s)

Mechanical wave velocities by CFWI detects myocardial dysfunction in acute coronary syndrome. Elevated basal AK wave velocity was independently associated with myocardial dysfunction where AK wave velocity ≥2.3 m/s provided a good sensitivity and ≥3.0 m/s a good specificity for detecting regional wall motion abnormalities. The feasibility of measuring the AK wave was good, whereas MVC and AVC waves had lower feasibility and were inadequate for assessment of myocardial function. Feasibility variations between AK and MVC/AVC waves suggest differences in wave propagation dynamics or intrinsic wave properties.

Illustration Clutter Filter Wave Imaging

Risk of myocardial dysfunction

Contributors

K Andresen
K Andresen

Author

Oslo University Hospital Rikshospitalet Oslo , Norway

S Fadnes
S Fadnes

Author

K Haugaa
K Haugaa

Author

T Edvardsen
T Edvardsen

Author

Oslo University Hospital Rikshospitalet Oslo , Norway