Transcatheter aortic valve replacement in a bicuspid aortic valve with membranous interventricular septum aneurysm communicating with aortic root: a case report
European Heart Journal - Case Reports

Abstract
Membranous interventricular septum aneurysm (MISA) is a rare abnormality occurring in 0.3% of patients with congenital heart disease, which thereby increases anatomical complexity.
Transcatheter aortic valve replacement (TAVR) procedure was planned for a 71-year-old female patient from East Asia with a type 1 bicuspid aortic valve diagnosed with severe aortic stenosis by transthoracic echocardiography (TTE). Pre-procedural multidetector computed tomography (MDCT) clearly revealed an extremely horizontal aorta and a MISA originating from the sub-annulus with the upper edge extending 7.2 mm above the annulus. A probable communicating flow between the left ventricle and the aorta was confirmed by reviewing the TTE images. Moreover, there was a calcified raphe between the left- and right-coronary cusps. A downsized balloon-expandable valve (a 23 mm Sapien 3 valve with an additional 2 mL dilation) was therefore chosen and deployed with a 100/0 aortic/ventricular ratio position. The TTE post-implantation indicated a trace perivalvular leakage. The cardiac MDCT performed post-procedure, at the 6-month, and 12-month follow-ups demonstrated complete sealing and significant healing of the aneurysm.
Transcatheter aortic valve replacement utilizing a balloon-expandable valve was successfully performed for a case with membranous interventricular septum aneurysm extending above the annulus. Comprehensive imaging analysis before the procedure is crucial for TAVR with challenging anatomical conditions.
Contributors

Ziwei Xi
Author

Jing Yao
Author

Guangyuan Song
Author

Christoph Sinning
Author

Hesham Bahaa
Author

Devika Kir
Author

Niklas Schenker
Author
You may be interested in


