Pacing lead extraction in the management of tricuspid regurgitation: a case report
European Heart Journal - Case Reports

Abstract
Patients with a cardiac implantable electronic device (CIED)-induced tricuspid regurgitation (TR) have an increased mortality and morbidity. However, the impact of CIED-lead extraction and its indications are not well-defined.
A 69-year-old woman presented with recurrent hospital admissions for right heart failure refractory to medical therapy, on the background of a single-chamber permanent pacemaker (Biotronik) implanted 6 years ago for tachycardia–bradycardia syndrome. Transoesophageal echocardiography identified severe TR which was predominantly CIED-induced from a lead impingement of the posterior tricuspid valve (TV) leaflet preventing adequate leaflet coaptation. This had progressed to cause a degree of secondary functional TR. The patient underwent pacing lead extraction followed by epicardial lead placement via minithoracotomy, with significant symptomatic and echographic improvement of TR.
CIED-induced TR from a lead impingement of TV leaflets carries the highest risk of TR and its consequences. This case illustrates the significance of the relationship between CIED-leads and the TV, which impacts management strategy. We recommend a mechanistic approach and incorporating CIED-lead interaction with the TV apparatus as the underlying principle in developing future management guidelines for CIED-induced TR.
Contributors

Lynn Khor
Author

Kedar Madan
Author

Choon Huat Lee
Author

Hatem Soliman Aboumarie
Author

Christoph Sinning
Author

Ali Nazmi Calik
Author

Nuria Farre
Author

Megha Agarwal
Author

Nida Ahmed
Author
You may be interested in