Early and long-term outcomes after manual and remote magnetic navigation-guided catheter ablation for ventricular tachycardia
EP Europace Journal

Abstract
Remote magnetic navigation (RMN) is a safe and effective means of performing ventricular tachycardia (VT) ablation. It may have advantages over manual catheter ablation due to ease of manoeuvrability and catheter stability. We sought to compare the safety and efficacy of RMN vs. manual VT ablation.
Retrospective study of procedural outcomes of 139 consecutive VT ablation procedures (69 RMN, 70 manual ablation) in 113 patients between 2009 and 2015 was performed. Remote magnetic navigation was associated with overall higher acute procedural success (80% vs. 60%,
Remote magnetic navigation may improve clinical outcomes after catheter ablation of VT in patients with ischaemic cardiomyopathy. Further prospective clinical studies are required to confirm these findings.