Lead extraction for cardiac implantable electronic device infection: comparable complication rates with or without abandoned leads

EP Europace Journal

19 July 2019
Organised by: Logo
ESC Journals

Abstract

AbstractAims

Abandoned leads are often linked to complications during lead extraction, prompting pre-emptive extraction if leads become non-functional. We examined their influence on complications when extracted for device-related infection.

Methods and results

All patients undergoing lead extraction for device-related infection from 2006 to 2017 in our hospital were included. The primary endpoint was major complications. Out of 500 patients, 141 had abandoned leads, of whom 75% had only one abandoned lead. Median cumulative implant times were 24.2 (interquartile range 15.6–38.2) and 11.6 (5.6–17.4), respectively years with or without abandoned leads. All leads were extracted only with a femoral approach in 50.4% of patients. Mechanical rotational tools were introduced in 2014 and used in 22.2% of cases and replacing laser sheaths that were used in 5% of patients. Major complications occurred in 0.7% of patients with abandoned leads compared with 1.7% of patients with only active leads (P = 0.679). Failure to completely remove all leads was 14.9% and 6.4%, respectively with or without abandoned leads (P = 0.003), and clinical failure was 6.4% and 2.2% (P = 0.028), respectively. Procedural failure dropped to 9.2% and 5.7% (P = 0.37), respectively after the introduction of mechanical rotational tools. The only independent predictor of procedural and clinical failure in multivariate analysis was the cumulative implant duration.

Conclusion

Despite longer implant times, patients with abandoned leads did not have more major complications during lead extraction. Therefore, preventive extraction of non-functional leads to avoid complications at a later stage is not warranted.

Contributors

Frank Bracke
Frank Bracke

Author

Catharina Hospital Eindhoven , Netherlands (The)