Assessment of left ventricular ejection fraction after myocardial infarction using contrast echocardiography
European Heart Journal - Cardiovascular Imaging

Abstract
Despite its relatively high intra- and inter-observer variability for left ventricular ejection fraction (LV-EF) echocardiography is clinically still the most used modality to assess LV-EF. We studied whether adding a second-generation microbubble contrast agent could decrease this variability.
Forty-eight patients underwent transthoracic echocardiography in second-harmonic mode (SHI) with and without contrast within 5 days after an acute myocardial infarction. LV-EF was determined using the Simpson's biplane method. With contrast intra-observer variability decreased from 12.5 ± 11.5% to 7.0 ± 7.0% (
Echo contrast significantly improves intra- and inter-observer variability for LV-EF, both in patients with moderate-to-poor and good quality SHI echocardiograms.
Contributors

Marcel L. Geleijnse
Author

Sing-Chien Yap
Author

Ron T. van Domburg
Author

Elena Biagini
Author

Wim B. Vletter
Author

Folkert J. Ten Cate
Author