Accurate measurement of mitral annular area by using single and biplane linear measurements: comparison of conventional methods with the three-dimensional planimetric method
European Heart Journal - Cardiovascular Imaging

Abstract
The planimetry method using three-dimensional (3D) echocardiography is useful for providing an accurate mitral annulus area (MAA) value. However, this method is relatively unavailable. Therefore, we evaluated the accuracy of conventional methods for MAA measurement compared with that of 3D planimetry.
Two-dimensional (2D) and 3D transoesophageal echocardiography (TEE) were performed in 70 patients. The mitral annulus diameter (MAD) was measured using four standard TEE imaging planes: four-chamber (4Ch), two-chamber (2Ch), anterior–posterior (LAX), and commissure–commissure (CC). MAA was calculated using a single diameter based on that of a circle and using two diameters based on that of an ellipse. MAA measurements using the single 4Ch MAD method (
Conventional LAX/CC MAD can be recommended for MAA measurements in a diverse patient population. This method is applicable as an alternative to the 3D planimetric method, regardless of the mitral annulus shape.
Contributors

Shinichi Iwata
Author

Aylin Tugcu
Author

Yukiko Oe
Author

Agnes Koczo
Author

Kenei Shimada
Author

Takashi Muro
Author

Junichi Yoshikawa
Author

Minoru Yoshiyama
Author

Linda D. Gillam
Author

Rebecca T. Hahn
Author

Marco R. Di Tullio
Author

Shunichi Homma
Author