Myocardial T1 and extracellular volume fraction measurement in asymptomatic patients with aortic stenosis: reproducibility and comparison with age-matched controls
European Heart Journal - Cardiovascular Imaging

Abstract
(i) To establish the test–retest reproducibility of myocardial T1 and extracellular volume (ECV) fraction measurement in asymptomatic patients with moderate–severe aortic stenosis (AS), (ii) to compare reproducibility using motion-corrected (MOCO) parametric T1 maps for analysis vs
3 T cardiac MRI was performed twice on 10 patients (median interval 7 days) to assess reproducibility. An additional 40 patients and 22 asymptomatic controls underwent a single MRI. Native T1 and ECV were calculated by outlining the myocardium on T1 maps generated inline, and using an offline T1 fit on the MOCO multiple inversion-time raw image series, in the reproducibility cohort (
The test–retest reproducibility of myocardial T1 quantification using MOLLI is excellent in patients with AS and is highest using inline generated T1 maps for analysis. There was no difference in native myocardial T1 or ECV between asymptomatic patients with moderate–severe AS and age-matched controls without valve disease.
Contributors

Mark A. Horsfield
Author

Soliana Bekele
Author

Jamal N. Khan
Author

Andreas Greiser
Author

Gerry P. McCann
Author