Quantification of hypo-attenuated leaflet thickening after transcatheter aortic valve implantation: clinical relevance of hypo-attenuated leaflet thickening volume
European Heart Journal - Cardiovascular Imaging

Abstract
Our aim was to establish an objective, quantitative methodology for volumetric hypo-attenuated leaflet thickening (HALT) diagnosis and evaluate its clinical significance.
We prospectively enrolled 144 patients who underwent transcatheter aortic valve implantation (TAVI) between 2011 and 2016. At inclusion, cardiac computed tomography angiography (CTA), transthoracic echocardiography, and brain magnetic resonance imaging (MRI) were performed. We quantified HALT on CTA datasets by segmenting the inner volume of TAVI frame at the level of leaflets and extracted voxels between a threshold of −200 to 200 HU based on prior recommendation. The median HALT volume was 72 [inter-quartile range (IQR): 1–154] mm3 (intra- and inter-reader agreement: intra-class correlation coefficient = 0.92 and 0.94, respectively) and 79% (
Through systematic analysis of asymptomatic patients with TAVI, an objective and reproducible methodology was feasible for volumetric measurement of HALT. Anti-coagulation might have a protective effect against HALT. Ischaemic brain lesions and all-cause death were not associated with HALT; nevertheless, it might deteriorate prosthesis function due to its association with elevated AMG.
Contributors

Júlia Karády
Author

Astrid Apor
Author

Anikó I Nagy
Author

Márton Kolossváry
Author

Andrea Bartykowszki
Author

Bálint Szilveszter
Author

Judit Simon
Author

Levente Molnár
Author

Ádám L Jermendy
Author

Alexisz Panajotu
Author

Ferenc I Suhai
Author

Andrea Varga
Author

Ronak Rajani
Author

Pál Maurovich-Horvat
Author

Béla Merkely
Author