Learning curve of visually-guided laser balloon ablation of paroxysmal atrial fibrillation
European Heart Journal

Abstract
Type of funding sources: None.
The visually-guided laser balloon (VGLB) is a compliant, variable-diameter balloon that delivers laser energy around the pulmonary vein (PV) ostium under real-time endoscopic visualization. However, limited data exist in Japan thus far. Therefore, we determined the safety, efficacy, and learning curve of the VGLB for PV isolation.
A total of 52 consecutive patients with paroxysmal atrial fibrillation were prospectively enrolled and divided into 3 groups (T1 = 15 patients, T2 = 15 patients, T3 = 22 patients). All patients underwent PV isolation by 2 operators using the VGLB. The operators were experienced in radiofrequency and cryothermal procedures, but not in laser ablations.
Tables show the acute clinical results. Reversible phrenic nerve palsy occurred in 3.8%, with a trend towards a lower complication rate with increasing experience.
The VGLB was safe and effective for PV isolation, even for operators without any previous experience. Procedure time decreased after a learning curve of 30 cases. Abstract Figure. Procedural data and isolation rates