Normal values for native T1 at 1.5 T in the pericardial fluid of healthy volunteers

European Heart Journal - Imaging Methods and Practice

19 September 2023
Organised by: Logo
ESC Journals

Abstract

AbstractAims

T1 mapping cardiovascular magnetic resonance (CMR) imaging has been used to characterize pericardial effusions. The aim of this study was to measure pericardial fluid native T1 values in healthy volunteers to establish normal values.

Methods and results

Prospectively recruited volunteers (n = 30) underwent CMR at 1.5 T, and native T1 maps were acquired using a modified look-locker inversion recovery 5s(3s)3s acquisition scheme. A volume of pericardial fluid was imaged in a short-axis slice and in a slice perpendicular to the short-axis orientation. A reliable measurement had a region of interest (ROI) size > 10 mm2, coefficient of variation < 10%, and a relative difference < 5% between the two slice orientations. In 26/30 (87%) of volunteers, there was a sufficient amount of pericardial fluid to enable reliable measurement. Native T1 of pericardial fluid was 3262 ± 163 (95% normal limits 2943–3581 ms) and did not differ in the perpendicular slice orientation (3267 ± 173 ms, P = 0.75), due to sex (female 3311 ± 177 vs. male 3220 ± 142 ms, P = 0.17), age (R2 = 0.03, P = 0.44), heart rate (R2 = 0.005, P = 0.7), or size of the ROI (0.06, P = 0.23).

Conclusion

This study shows that T1 values can be reliably measured in the pericardial fluid of healthy volunteers. It is the first to report normal reference ranges for T1 values at 1.5 T in the pericardial fluid of healthy volunteers.

Contributors

Simon Thalén
Simon Thalén

Author

Karolinska University Hospital Stockholm , Sweden

Peder Sörensson
Peder Sörensson

Author

Karolinska Institute Stockholm , Sweden

Martin Ugander
Martin Ugander

Author

University of Sydney Sydney , Australia