To evaluate if public reporting of pacemaker implantation-associated mortality is meaningful in a large contemporary patient cohort.
The database of the obligatory external quality control programme in the Federal State of Hessen, Germany, of patients undergoing permanent pacemaker (PPM) implantation was evaluated retrospectively. We compared the baseline features of patients who died compared with those who did not during hospitalization after PPM. Of 5079 patients who underwent PPM implantation in 2009, 74 (1.5%) died during the hospital stay. Cause of death was available in 70/74 patients (94.6%) who died. Deceased patients were older (79.6 ± 8.7 vs. 76.3 ± 9.9 years,
Mortality associated with PPM implantation in vast majority of cases was not related to the procedure, but to comorbidities and other existing diseases at the time of PPM implantation. Thus, PPM implantation in-hospital mortality should not be chosen for public reporting comparing hospital quality, even after adjusting for baseline risk.