Before the discovery of contact-force guidance, eliminating pacing capture along the pulmonary vein (PV) isolation line had been reported to improve PV isolation durability and rhythm outcomes. DRAGON (UMIN-CTR, UMIN000015332) aimed to elucidate the efficacy of pace-capture-guided ablation following contact-force-guided PV isolation ablation in paroxysmal atrial fibrillation (AF) patients.
A total of 156 paroxysmal AF patients with AF-trigger ectopies from any of the four PVs induced by isoproterenol were randomly assigned to undergo pace-capture-guided ablation along a contact-force-guided isolation line around AF-trigger PVs (PC group,
Pace-capture-guided ablation performed after contact-force-guided PV isolation demonstrated no improvement in PV isolation durability or rhythm outcome.