In order to bring you the best possible user experience, this site uses Javascript. If you are seeing this message, it is likely that the Javascript option in your browser is disabled. For optimal viewing of this site, please ensure that Javascript is enabled for your browser.

The free consultation period for this content is over.

It is now only available year-round to ESC Professional Members, Fellows of the ESC, and Young combined Members

Aortic shape synthesiser - understanding anatomical variations of the thoracic aorta

Session Poster Session 3

Speaker Hans Lamecker

Event : ESC Congress 2019

  • Topic : e-cardiology / digital health, public health, health economics, research methodology
  • Sub-topic : Computer Modeling and Simulation
  • Session type : Poster Session

Authors : L Gundelwein (Berlin,DE), A Szengel (Berlin,DE), H Ramm (Berlin,DE), L Goubergrits (Berlin,DE), M Kelm (Berlin,DE), H Lamecker (Berlin,DE)

Authors:
L. Gundelwein1 , A. Szengel1 , H. Ramm1 , L. Goubergrits2 , M. Kelm2 , H. Lamecker1 , 11000shapes - Berlin - Germany , 2Charité - Universitätsmedizin Berlin, Institute for Computational and Imaging Science in Cardiovascular Medicine - Berlin - Germany ,

Citation:
European Heart Journal ( 2019 ) 40 ( Supplement ), 1397

Introduction: Population-based models of morphological variability are useful for automating medical image processing tasks, diagnosis, device and tool design, education and training as well as exploratory hypothesis formation in clinical research. We present a method to (a) generate such a model of the thoracic aorta, (b) explore the morphological characteristics of the underlying population in an intuitive visual and quantitative manner, and (c) correlate clinical parameters with morphological descriptors. With our approach one can synthesise new anatomically plausible aorta shapes, based on basic and intuitive parameter queries (e.g. shapes with a given stenosis degree and position).

Methods: We use a statistical shape model (SSM) as a compact mathematical representation of the geometric variability contained in a training population of 150 aortas of healthy, coarctation of the aorta and aortic valve disease patients. We describe each shape by centerlines of the aorta and supra aortic branches with inscribed radii at each centerline point. All shapes are registered with each other into a common shape space, where we compute a statistical mean as well as characteristic modes of variation. New shapes are synthesised by randomly sampling the shape modes and validated based on the underlying parameter distributions of the training data. This way we generate a representative database of anatomically plausible shapes. Querying the database with basic morphological parameters (e.g. aortic length, diameter, height-width ratio, stenosis size and position) returns a set of matching shapes based on the L1 norm on the given parameters.

Results: The first shape modes show that the greatest variance can be found in size, compactness, distance between supra-aortic branches and height-width ratio. In order to validate that the SSM represents the population well, 20 cases are left out when building it. It is then aligned to the unseen cases and the distance in coordinates and radii is evaluated. The matching error of only 1.54 mm in centerline coordinates and 0.16 mm in radii indicates that the SSM represents the population well.

100000 plausible shape instances are synthesised and queried with a set of 6 morphological parameters with a mean similarity score of 0.04. Application of the Kolmogorov-Smirnov statistics confirms that the morphological parameters of the synthesised and training shapes belong to the same distribution. Querying with a subset of parameters, e.g. a stenosis degree of 80 and stenosis position at the isthmus, allows to examine specific anatomical manifestations, see Fig. 1.

Conclusions: The SSM methodology gives new insights into the correlation of morphological and clinical parameters within a given population. It allows to synthesise large numbers of representative new shapes, e.g. for data augmentation in artificial intelligence applications or large-scale functional analysis, e.g. via computational fluid dynamics simulation.

Aortic shape synthesiser pipeline

The free consultation period for this content is over.

It is now only available year-round to ESC Professional Members, Fellows of the ESC, and Young combined Members

Get your access to resources

Join now
  • 1ESC Professional Members – access all ESC Congress resources 
  • 2ESC Association Members (Ivory, Silver, Gold) – access your Association’s resources
  • 3Under 40 or in training - with a Combined Membership, access all resources
Join now

Our sponsors

ESC 365 is supported by Bayer, Boehringer Ingelheim and Lilly Alliance, Bristol-Myers Squibb and Pfizer Alliance, Novartis Pharma AG and Vifor Pharma in the form of educational grants. The sponsors were not involved in the development of this platform and had no influence on its content.

logo esc

Our mission: To reduce the burden of cardiovascular disease

Who we are